SAMHOON Mainly Works for CBRN Facilities, Special Doors And Thermal Sight
No | Technology | Size | Coalition | Coalition Period | Item Type | Others |
---|---|---|---|---|---|---|
1 | BLAST DOOR Earthquake Resistant Design Testing | CP-A₂ | LICENSED
PROFESSIONAL ENGINEER W.S.JUNG |
1996. 04. 18
∼ 1996. 12. 02 |
Blast Door | Reference |
2 | Gasket Certificate | ASTM D2000 | Korea Testing and Research Institute for Chemical Industry | 1997. 09. 06
∼ 1997. 09. 11 |
EDPM | Reference |
3 | Air Leakage Testing | ASTM E 283 | Korea Institute of Machinery & Materials | 1996. 09. 30
∼ 1997. 10. 30 |
Blast Door | Reference |
Reference | ||||||
4 | Fire Test | UL 10B(3/Hr) | Fire Insurers Laboratories of Korea | 1999. 03. 13
∼ 1999. 03. 25 |
Fire Door | Reference |
5 | Air Leakage Test | ASTM E 283 | CNC | 1999. 06. 11
∼ 1999. 06. 19 |
Fire Door | Reference |
6 | Fire proof Test | UL 10B(3/Hr) | Fire Insurers Laboratories of Korea | 1999. 12. 07
∼ 2000. 02. 06 |
Bullet Resistant Door | Reference |
7 | Bullet proof Test | UL 752 | Agency for Defense Development | 1999. 11. 07
∼ 2000. 02. 20 |
Bullet Resistant Door | |
8 | Water-proof Door | ASTM
D2000 |
Self-developed | 2001. 04. 16
∼ 2001. 06. 30 |
Switchgear for speed reducing gear | |
9 | Water-proof Door | Water level 4.5M | Self-developed | 2001. 05. 20
∼ 2001. 08. 20 |
Switch for Passive Hydraulic cylinder | |
10 | Air filter | Air cleaner | Self-developed | 2001. 07. 10
|
Filter for non-noise | |
11 | Water protection door development (Structure stability investigates) | For the
water level 4.5M |
Yeawoo
construction structure laboratory |
2002. 03. 28
∼ 2002. 04. 22 |
Over Head
Type |
|
12 | Water protection door development (The electric computer interpretation of the water tight qualities ) | For the
water level 4.5M |
Korean simulation technique .Co |
2002.03.28
∼ 2002. 04.22 |
Over Head
Type |
Reference |
13 | Water protection door development (Structure stability investigates) Air Leakage Testing | For the
water level 10.6M |
Korean simulation technique .Co |
2002. 04. 23
∼ 2002. 06. 04 |
Over Head
Type |
Reference |
14 | Water protection door development (The electric computer interpretation of the water tight qualities) | For the
water level 10.6M |
Korean simulation technique .Co |
2002. 04. 23
∼ 2002. 06. 04 |
Over Head
Type |
Reference |
15 | Water-proof Door | water
level 1.3M |
Sliding Type | 2002. 09. 04
∼ 2002. 11. 20 |
Gear Box Type | |
16 | Blast-proof Door | 60 Psi | Swing Type | 2002. 10. 29
∼ 2002. 12. 15 |
Link Gear
Box Type |
|
17 | Blast-proof Door | 100 Psi
130 Psi |
Concrete Type | 2002. 11. 02
∼ 2002.1 2. 15 |
Shotting
Bolts Type |
|
18 | Grading of Air tightness | CNS 11527 | CTC | 2003. 05. 22 | Stainless Fire door Reference | Reference |
19 | Blast-proof Door | 558psi(40bar) | Agency for Defense Development | 2002. 05. 26
∼ 2002. 05. 30 |
Reference | |
20 | Fire test | UL 10 B
(3/Hr) |
UL | 2003. 06. 23 | Stainless Fire door | Reference (R21261) |
21 | UL Fire Door Frame | UL 10 B (3/Hr) | UL | 2003. 10. 14 | Stainless Fire door Frame | Reference (R21544) |
22 | Fire resistance test for Window assemblies | UL 10 B (1/Hr) | KICT | 2004. 06. 02 | 12.5 psi | Reference |
23 | Fire resistance test for Door assemblies | UL 10 B (2/Hr) | KICT | 2004. 06. 04 | 12.5 psi | Reference |
24 | Blast Proof Door | 25 Bar | DongYang Co.Ltd | 2004. 06. 10 | swing type | Reference |
25 | UL Fire Door | UL 10 B
(1 1/2Hr) |
UL | 2005. 01. 05 | VISION PANEL | |
26 | UL Fire Door | UL 10 B
(1 Hr) |
UL | 2005. 01. 05 | VISION PANEL | |
27 | Water-proof Door | 23.0m Head Water Pressure | Self-developed | 2006. 02. 20
~ 2006. 02. 23 |
SMART in Mylaysia | |
28 | Test of Structure for Blast Proof Door(13 psi) | ASTM E 330 | CNC | 2008. 06. 25 | KRCC | |
29 | Bullet Resistant Door | EN 1522 Class FB6 (Velocity 830±10m/s) | Korea Military Academy | 2008. 09. 19 | QATAL PEARL GTL | |
30 | Bullet Resistant Door | UL 752 Level 8 (Velocity 838m/s) | Korea Military Academy | 2008. 09. 30 | QATAL PEARL GTL | |
31 | Frame Anchor Bolt | M12 x 123L | Korea Testing and Research Institute | 2009. 01. 02 | GI Type | |
32 | Frame Anchor Bolt | M12 x 123L (Stainless Type) | Korea Testing and Research Institute | 2009. 01. 02 | 316L Type | |
33 | Air Leakage Test (Sliding Door Assembly) | ASTM E 783 | CNC | 2009. 03. 16 | Expressway YOOSU Tunnel | |
34 | Hollow Metal Door | ANSI A 250.4 (Class A) | Lloyd’s Register | 2009. 07. 20 | US Army in Korea | |
35 | Security Door | EN-1143-1 Level VII | Lloyd’s Register | 2009. 08. 04 | Central Bank in Iran |